2. Basic Commands
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Checksum
\x07
Stop
\xff
2.34 Standby Timer, Read
Description
Reads the actual Standby Timer value
Command
Command [0]
\x21
Command [1]
\x98
Returned Data
Unsigned word representing the standby time value:
Data[0] = msb
Data[1] = lsb
range: 180 to 3600 seco nds
0 seconds = Standby timer OFF
Example
Reads the actual standby timer value, being \x00 (Timer OFF)
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\x98
Checksum
\xba
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Checksum
\x07
Stop
\xff
R5976884 RLM SERIES 04/04/2006 73