Barco RS232 Manual de usuario Pagina 45

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 171
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 44
2. Basic Commands
Example
Reads the actual Phase value of the projector, the awnser being \x1a
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\x06
Checksum
\x28
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Checksum
\x07
Stop
\xff
Receive (Answer)
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\x06
Data [0]
\x1a
Checksum
\x42
Stop
\xff
2.7.35 Minimum Phase, Read
Description
Reads the minimum (range) Phase value of the projector
Command
Command [0]
\x26
Command [1]
\x06
Returned Data
Data [0] = minimum Phase value
Example
Reads
the minimum Phase value of the projector, the awnser being \x00